This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Catalogue
Master Index
Data
Centre
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Metadata Editor Record List Alias List Editor
Data Centre
Data Type Editor
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Manaj, S., & Kim, S. T.
Title
Techniques for Measuring Carbon and Oxygen Isotope Compositions of Atmospheric CO2 via Isotope Ratio Mass Spectrometry (IRMS)
Year
2020
Publication Outlet
Rapid Communications in Mass Spectrometry, 35, e8995.
DOI
https://doi.org/10.1002/rcm.8995
Citation
Manaj, S., & Kim, S. T. (2020). Techniques for Measuring Carbon and Oxygen Isotope Compositions of Atmospheric CO2 via Isotope Ratio Mass Spectrometry (IRMS). Rapid Communications in Mass Spectrometry, 35, e8995. https://doi.org/10.1002/rcm.8995
Abstract
Measuring the stable isotope compositions of atmospheric CO2 is common in earth and atmospheric sciences, and various analytical methods have been developed utilizing continuous-flow (CF) or dual-inlet (DI) isotope ratio mass spectrometry (IRMS). Air is typically collected via passive, manual, or automated collection methods and the volume of the air sample ranges from 10 to 300 mL for CF-IRMS to >1 L for DI-IRMS to yield a measurable amount of atmospheric CO2 gas. It has been determined that the integrity of vials and flasks for air sample storage can be compromised after 3 days of air collection for δ13C values and within 10 hours for δ18O values. Air samples must be purified after collection to remove constituents of air, such as Ar, O2, N2, N2O, and water vapor, to avoid isobaric interferences during mass spectrometric measurement. Purification is generally undertaken by utilizing commercial or custom-made preconcentration devices, the blanking method for CF-IRMS, or an offline/online cryogenic separation using a vacuum line for DI-IRMS. Ambient N2O is a component of air that may affect analytical results and thus must either be corrected for or be removed using a gas chromatographic column. In some cases, water is removed during air collection by using a common chemical desiccant, magnesium perchlorate (Mg(ClO4)2), or by a dry ice/alcohol mixture (−78°C). Lastly, a linearity issue for IRMS due to the low amount of purified CO2 from a typical ambient air sample must be considered. In general, analytical precisions of 0.02–0.21‰ and 0.04–0.34‰ for CF-IRMS and 0.01–0.02‰ and 0.01–0.02‰ for DI-IRMS are expected for δ13C and δ18O measurements, respectively.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SFWF: Southern Forests Water Futures
Publication Stage
Published
Additional Information
SWF
Download Links
https://doi.org/10.1002/rcm.8995
© 2026 - WaterNet Version 2026-07-02
Global Water Futures Observatories
Powered by
G W F Net
T-2021-11-14-F1YPF3EoIerkKjcyDoWRbK5g Publication 1.0